VISIONVISION
3D model of an industrial plant built by VISION from a laser scan

Level of detail in industrial 3D models

Download the guide (PDF)

Detail and fit to the scan

We model plants and mechanical facilities from the point cloud. More detail means more modeling time and a larger file, so we choose the level by what the model will be used for.

Before modeling starts we agree two things with you: the level of detail for each kind of element, and the largest difference allowed between the model and the point cloud. One area or one kind of element can take a higher level than the rest.

Level 1 Overall shapes

Each element is shown by its overall shape and position: equipment as simple volumes, pipes with sharp corners, steel as solid sections. It suits layout studies of large installations and clash checks.

Pump station modeled at level 1

Level 2 The usual choice

Equipment takes its real form, pipes get their bends, flanges and valves, steel is modeled with its true sections, and stairs and handrails are included. It balances detail against modeling time and suits most engineering uses.

Pump station modeled at level 2

Level 3 Connections and fittings

Adds bolted connections, nozzles, supports, base plates, cable ladders and small fittings. It is used for visualization and for design work where space is tight. It takes noticeably more modeling time, so it is often applied to selected areas only.

Pump station modeled at level 3

The same components at each level

Pipe bend

Pipe bend at level 1
Pipe bend at level 2
Pipe bend at level 3

Valve

Valve at level 1
Valve at level 2
Valve at level 3

Flanged joint

Flanged joint at level 1
Flanged joint at level 2
Flanged joint at level 3

Steel column and beam

Steel column and beam at level 1
Steel column and beam at level 2
Steel column and beam at level 3

Pipe support

Pipe support at level 1
Pipe support at level 2
Pipe support at level 3

Pump set

Pump set at level 1
Pump set at level 2
Pump set at level 3

Vessel

Vessel at level 1
Vessel at level 2
Vessel at level 3

Stair and handrail

Stair and handrail at level 1
Stair and handrail at level 2
Stair and handrail at level 3

Cable tray

Cable tray at level 1
Cable tray at level 2
Cable tray at level 3

Modeling tolerance

Pipes sag and beams deflect, so a straight element in the model never lies exactly on the scan. The tolerance is the largest distance we accept between the two. A tighter tolerance means more segments and more modeling time. We set its value with you, for pipes and for structural members, and record it in the scope of work.

A sagging pipe from the scan beside the straight pipe of the model, with the largest distance between them marked

Choosing a level

Tell us what the model is for and we will recommend a level for each kind of element. Detail beyond what the use needs adds modeling time without adding value.

Request a quotation

Other levels of detail